General Information
| Product ID: | 3AXD50000183012 |
| ABB Type Designation: | ZCU-12 PACKED SP |
| Catalog Description: | ZCU-12 PACKED SP; CONTROL UNIT |
| Long Description | ZCU-12 PACKED SP |
| Dimensions: | 27.2x13.8x6.8cm |
| Weight: | 0.55kg |
Core Description
The ZCU-12L 3AXD50000794058 is a premium, system-critical ABB industrial drive central control unit engineered for variable speed converter applications. Designed to execute core processing logic, this device functions seamlessly with primary control programs to deliver flexible system parameter tuning, modular memory scaling, and stable real-time loop orchestration across high-demand industrial processing networks.
Specific Application
Ordering Information
|
Technical & Commercial Metric |
Selected Factory Specification Details |
|
Historical Product ID |
3AXD50000794058 |
|
Current Factory Replacement Kit |
3AXD50000183012 |
|
ABB Type Designation |
ZCU-12 PACKED SP / ZCU-12L |
|
Catalog / Invoice Description |
CONTROL UNIT |
|
Product Functional Type |
Spare_Parts |
|
Core Frame Size Category |
Spare_Parts |
|
Minimum Order Quantity |
1 piece |
|
Product Net Width |
70 mm |
|
Product Net Height |
272 mm |
|
Product Net Depth / Length |
138 mm |
|
Net Device Weight |
0.55 kg (Gross Weight: 0.55 kg) |
|
Gross Volume Envelope |
2.628 dm³ |
Where Used (as part of "kit")
|
Identifier |
Type |
|
3AUA0000151040 |
Kit |
|
3AUA0000151291 |
Kit |
|
3AXD50000010345 |
Kit |
|
3AXD50000556106 |
Kit |
|
3AXD50000600885 |
Kit |
|
3AXD50000624195 |
Kit |
|
3AXD50000624201 |
Kit |
|
3AXD50000624225 |
Kit |
|
3AXD50000626182 |
Kit |
|
42003291 |
Kit |
|
42003292 |
Kit |
|
42003293 |
Kit |
|
42003294 |
Kit |
|
42003295 |
Kit |
|
42003515 |
Kit |
Installation & Troubleshooting FAQ
Q1: What unique battery modification must be carried out when installing this board into ACS880-14/34, ACH580-34, or ACQ580-34 drives?
A: When deploying this control board within these specific drive models, the onboard backup lithium battery is entirely unnecessary for operations . You must physically extract the lithium battery from its holder prior to completing the installation.
Q2: Why is the newly mounted control card throwing an immediate firmware error or failing to boot?
A: This board mandates strict synchronization with an external memory cartridge and matching peripheral firmware. Ensure a compatible ZMU-02 or ZMU-03 memory unit is fully seated. Furthermore, if operated inside an ACS880-14/34, ACH580-34, or ACQ580-34 setup, verify that your ISU-side memory firmware is updated to version v3.41.0.0 or later to avoid startup blockades.
Q3: What logistics factor causes unexpected delivery time variations when ordering this hardware?
A: This control unit configuration may pack localized backup lithium batteries falling under international UN classifications 3181, 3090, or 3091. Because these fall under hazardous material transport safety rules, they undergo rigorous shipping compliance screenings that can occasionally introduce localized transit delays.
Contact information
Please don’t hesitate to contact us if you have any questions or concerns before or after your purchase. We are committed to your 100% satisfaction.
Sales Manager:Stella
Email:sales6@apterpower.com
Whatsapp:+86 18159889985
We provide professional global shipping services to ensure your industrial automation parts and equipment arrive safely and on time. To meet different delivery requirements, we cooperate with internationally recognized logistics companies, including:FedEx/DHL/TNT/UPS/SF Express
Whether you require standard international shipping or urgent express delivery, we can arrange flexible logistics solutions tailored to your project schedule and destination.
For convenient and secure transactions, we accept T/T (Telegraphic Transfer) payment.
After order confirmation, our sales team will provide complete payment details and invoice information to ensure a smooth and efficient payment process.
We are committed to providing efficient delivery and dependable customer service for clients worldwide.
| ABB |
AC800F 3BDH000002R1 PM802F 3BDH000002R1 |
ABB |
AC800F 3BDH000011R1 SA801F 3BDH000011R1 |
ABB |
ACDU V1.01 |
|
ABB |
ACP201-02 3ADM2001132R0101 |
ABB |
ACS880-M04-014A-5 |
ABBABB |
ACS-AP-I 3AUA0000064885 |
|
ABB |
ACSM1-04AM-04A0-4 |
ABB |
AF260-30-11 1SFL537001R7011 |
ABB |
AFC094AE01 HIEE200130R1 |
|
ABB |
AFS655 AFS655-72GESSNHHX08.0.09 |
ABB |
AGPS-21C |
ABB |
AI610 3BHT300000R1 |
|
ABB |
AI620 3BHT300005R1 |
ABB |
AI635 3BHT300032R1 |
ABB |
AI830 3BSE008518R1 |
|
ABB |
AI835 3BSE008520R1 |
ABB |
AI845 3BSE023675R1 |
ABB |
AI845-EA 3BSE023675R2 |
|
ABB |
AI86-16 57087196 |
ABB |
AI880A 3BSE039293R1 |
ABB |
AI890 3BSC690071R1 |
|
ABB |
AI895 3BSC690086R1 |
ABB |
AI910N 3KDE175513L9100 |
ABB |
AI910S 3KDE175511L9100 |
|
ABB |
AI930N 3KDE175513L9300 |
ABB |
AI930S 3KDE175511L9300 |
ABB |
AI931N 3KDE175513L9310 |
|
ABB |
AI950N 3KDE175523L9500 |
ABB |
AI950S 3KDE175521L9500 |
ABB |
AO610 3BHT300008R1 |